INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Bisolid Automat OM-BAV04/10/2017/EN
18
Model identifier: Hot water solid fuel boiler Bisolid Automat 35.
Stoking mode: Automatic: it is recommended that the boiler be operated with a hot water storage
tank of a volume of at least 700 litre
Condensing boiler: no
Solid fuel cogeneration boiler: no
Combination boiler: no
Fuel
Preferred
fuel (only one):
Other suitable
fuel(s):
Log wood, moisture content
≤
25 %
no
yes
Chipped wood, moisture content 15-35 %
no
no
Chipped wood, moisture content > 35 %
no
yes
Compressed wood in the form of pellets
yes
no
Sawdust, moisture content
≤
50 %
no
no
Other woody biomass
no
no
Non-woody biomass
no
no
Bituminous coal
no
no
Brown coal (including briquettes)
no
no
Coke
no
no
Anthracite
no
no
Blended fossil fuel briquettes
no
no
Other fossil fuel
no
no
Blended biomass (30-70 %) and fossil fuel briquettes
no
no
Other blend of biomass and fossil fuel
no
no
Characteristics when operating with the preferred fuel:
Seasonal space heating energy efficiency
ƞ
s
[%]: 86
Energy efficiency index EEI:
А
+