INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Bisolid Automat OM-BAV05/02/2018/EN
45
6.6. BURNER GSM CONTROL MODULE (OFFERED AS AN OPTION)
The control of the pellet burner through a GSM module is done by sending SMS commands. It
allows for stopping, starting and current status monitoring. (See Section "SMS Commands")
6.7. METHODS FOR FORMING THE DESIRED TEMPERATURE
6.7.1. MANUAL DETERMINATION OF THE HEATING WATER
ASSIGNMENT (
Т
b set)
In this case, the assigned values are independent of other factors such as external
temperature and room temperature, a value is selected to be maintained. (See Section
Programming
“
Service Settings").
There is provided possibility for room thermostat using, and this thermostat to be connected to
the the rear panel of the boiler.
6.7.2. DETERMINATION OF THE HEATING WATER ASSIGNMENT BY
ROOM THERMO-REGULATOR
This mode is applicable only if using contact room thermostats with
"independent outlet"
. (See Section Programming "Service Settings).
The room thermostat may be used
ONLY
when operating the boiler with the
preferred fuel (wood pallets) without adding other suitable fuel!
Time for optimization.
When using optimization time, the number of fluctuations of the setup values of the heating
water are decreased, which leads to much better regulation of the heating water. It can be
selected from 0 to 60 min, with a pitch of
5 minutes
. (See Section Programming
“
Service
Settings").
When the room thermo-regulator is switched on or off and there is no optimization (0 minutes),
the setup values of the heating water are:
At switching on – maximum.
At switching off – minimum.
Т
,
Wmax
ON
OFF
Wmin
W
without
optimization
Т
,
Wmax
ON
OFF
Wmin
W
with optimization