Testing boiler connections for leakages.
Checking fittings including nozzles, valves, pressure valves for reliable opening and
closing.
Testing and cleaning the water filter if needed.
Checking and cleaning the expansion tank if needed.
Testing the pressure sensor. Cleaning and replacement if needed.
Operation and safety control check of the boiler hydraulic system.
Testing proper operation of the unloading valve.
5.7. TUBE PELLET BURNER CLEANING
The system for cleaning of tube pellet burner with rotary self-cleaning from Bisolid GP xx R tsc
consists of:
Mechanism for tube rotation.
Motor-gear for mechanism rotation.
PC board that controls the mechanism.
The cleaning of the rotary tube pellet burner is carried out in a certain algorithm, in the
combustion process.
The adjustment of the automatic cleaning system of a rotary tube pellet
burner from Bisolid GP xx R tsc must be performed by a certified staff.
In case of a warning alarm message for the failure of the pellet burner,
the user
is obliged
to check for possible accumulation of fuel in the burner tube and fuel
transport auger and in the presence of fuel to remove it.
The number and frequency of cleaning of the burner depend largely on the
quality of the wood pellets. Fuel is necessary to meet the standard
EN ISO 17225-2:2014, classes A1, A2 and B.
5.8. TUBE PELLET BURNER MAINTENANCE
The time for cleaning (rotating tube) of the combustion chamber of rotary tube pellet burner
Bisolid GP xx R tsc and cleaning the tube itself depends on the type and quality of the used
fuel.
Before taking action on cleaning, servicing and repair, the pellet burner must
be switch off from the electricity supply.
When cleaning the tube of pellet burner Bisolid GP xx R tsc need to be removed combustion
head of the burner, as shown in the diagram in the following figure.