If any abnormality occurs, carefully read this manual and make the following checks and
actions. If abnormality can not be eliminated, contact your lift supplier for advice.
・ Investigate the cause and push
the reset button
・ Contacting point of Magnet Contactor is burnt ・ Replace magnet contactor
・ Cable connection fault
・ Connect the cable
・ Disconnected cable of motor or burnt motor
・ Replace motor
・ Bad contact of Push-Button Switch
・ Replace Push-Button Switch
・ Motor is running reverse direction
・ Rewire 2 wires out of 3 wires
・ Hydraulic oil is not full
・ Fill the oil
・ Gear Pump does not vacuume oil
・ Replace Gear Pump
・ Roller at bottom of link is stuck with obstacles
・ Coil of Lowering Valve is not working
・ Replace coil
・ Filter inside Lowering Valve is clogged
・ Replace filter or clean up
・ Shoe at bottom of link is stuck with obstacles
・ Adjust the Air Filter Regulator
・ Oil leak from Lowering Valve
・ Replace Lowering Valve
・ Defective seals of cylinder
・ Replace seals
・ Defective Check Valve
・ Oil leak from piping
・ Tightening
・ Loose tightening of manual Lowering Valve
・ Tightening
・ Oil filter is clogged
・ Clean up, or replace oil filter
・ Filter of Valve Manifold is clogged
・ Clean up, or replace filter
・ Air is in the oil
・ Fill the oil, or replace oil
・ Air get in from suction side
・ Tightening the piping
・ Wear of Cylinder seals
・ Replace seals
・ Hyd. Oil get heated (over 45℃)
・ Replace with recommended oil
・ Lack of lubrication at bearing of link
・ Lubricate
・ lack of hyd. Oil
・ Fill the oil
Lift does not rise
・ Fuse is blown
・ Replace fuse
and lower
・ No primary power supplied
・ Turn on primary power
Rising speed is slow
Abnormal Noise
・ Clean up, or replace Check Valve
・ Lowering Stop Hook is engaged with Safety Rack
・ Remove obstacles
or adjust the supplied air pressure
・ Air pressure supplied is below 0.7 MPa
Lift Does Not Lower
Lift goes up but
gradually lowers
・ Raise the lift once and then lower
・ Thermal relay of Magnet Contactor is running
・ Remove obstacles
Lift Does Not Rise
(Motor Not Running)
Lift Does Not Rise
(Motor Is Runnnig)