Bird Site Analyzer
62
Figure 24 Select Cable Type from List
3. Continue to the next topic in this section (Setting
the Distance and Units, page 63)
Distance
Scale
Limit
Line
Smooth
Low
Cbl Type
Type
Vp@1Ghz
Loss
5062
5088
5092
5128
5228
5328
5438
FSJ1-50A
0.8200
0.8800
0.8200
0.8800
0.8800
0.8800
0.8800
0.8400
0.1447
0.1047
0.1089
0.0745
0.0420
0.0312
0.0259
0.1968
Fault Location
[
]
238 Pts
1
2
3
4
5
6
7
Step
Action
1
Press the Config key
2
Press the Cbl Type soft key
3
Press the right or left scroll keys to select
Cable List
4
Press the up or down scroll keys to open
the cable list
5
Press the up or down scroll keys to select
an item on the list
6
Press the Enter key to accept the selection
7
Press the Esc key to exit the configuration
screen
Summary of Contents for SITE ANALYZER SA-1700EX
Page 2: ...This page is not blank...
Page 8: ...Bird Site Analyzer vi...
Page 9: ...vii...
Page 30: ...Bird Site Analyzer 16...
Page 142: ...Bird Site Analyzer 128...
Page 148: ...Bird Site Analyzer 134...
Page 159: ...Maintenance 145 Measured Return Loss dB...
Page 167: ...Maintenance 153 the number of data points you wish measure 238 475 949...