Complementary Cumulative Distribution Function (CCDF)
CCDF measures the amount of time the power is
above a threshold. Equivalently, it is the probability
that any single measurement will be above the thresh-
old. The WPS samples the power over a 300 ms win-
dow and compares it to a user-specified threshold, in
Watts. The time above the threshold relative to the
total time is the CCDF.
Setting the CCDF Limit
CCDF
100 W Signal
80 W Threshold
20% CCDF
80 W
0 W
50 W
100 W
Press from
Measure
Power Mode
Scroll to
CCDF Lim
Enter the
new value
Fwd
0.00 KWatts
Video BW
4.5KHz
Zero
Calibrate
Recall
Setups
Measure Power Mode
Configuration Screen
Offset
FullScale
0.00 dB
150.00 Watts
1 .00
00
Watts
CCDF Lim