Utilities
131
FM Modulation
The Bird Site Analyzer uses FM modulation to
improve its immunity to interfering signals. Under
certain circumstances, such as while making cable loss
or other high reflection measurements with long
cables, FM modulation may reduce signal quality. In
that case, the modulation should be turned off.
y
FM modulation is on by default, and will be turned
back on whenever the unit is reset to defaults.
y
FM modulation is automatically turned off while
the unit is in Cable Loss Mode and returned to its
previous state on exiting Cable Loss Mode.
y
Saving a setup saves the status of the FM
modulation.
Press to
return all
settings to
factory
presets
Rtn To
Defaults
FM Mod
Printer
System
Return to defaults executed.
Model SA-1700, 25 - 1700 MHz
SN: 00000000
25 Nov 2002
Utility Mode
Summary of Contents for SITE ANALYZER SA-1700EX
Page 2: ...This page is not blank...
Page 8: ...Bird Site Analyzer vi...
Page 9: ...vii...
Page 30: ...Bird Site Analyzer 16...
Page 142: ...Bird Site Analyzer 128...
Page 148: ...Bird Site Analyzer 134...
Page 159: ...Maintenance 145 Measured Return Loss dB...
Page 167: ...Maintenance 153 the number of data points you wish measure 238 475 949...