WINTERIZING
If you drain your spa for the winter, you should disconnect
the tubing from the cell, empty the cell of water completely
and store it indoors. The power to the spa (and BiO2) should
be shut off.
Your spa should not be filled with water without
the heater set above freezing
.
TROUBLESHOOTING
DIAGNOSTIC FEATURE
The BiO2 touch control pad will help troubleshoot the system
without the need to open the spa's equipment compartment. The
troubleshooting guide will ask you to check the diagnostics
for certain conditions as follows:
Press both the
SET LEVEL
and
BLAST
buttons simultaneously.
Keep both buttons pressed until a "
t
" appears, (see
illustration below) then release the buttons. A sequence of
letters and numbers will be displayed, one digit at a time,
that will indicate how the system is operating and the
potential trouble. The sequence will stop automatically after
2 cycles. For troubleshooting purposes, please write this
sequence down in order. You may be asked for them by your
dealer or the BioQuest Help Desk Technician.
DIAGNOSTIC READOUT SEQUENCE
CODE
DESCRIPTION
VALUE RANGE
Pc
Motor current
0.4 to 0.7
Cc
Cell current
0.9 to 3.0
Cu
Cell voltage
13.0 TO 17.0
Read outs in these ranges indicate proper functioning.
TROUBLESHOOTING
CONDITIONS
My BiO2 unit is not working.....
1.)
What does the water look like?
a. Cloudy: Possible low or no Bromine, or filtration