seconds.
4. A Cell wire may be disconnected.
a. Inspect the
white and green
Cell wire
connections and reconnect if needed.
5. Cell cable may not be connected at the BiO2
Power Supply.
A
High Motor Current
Debris in cell or motor failure
a. Replace cell.
P
Low Cell and Motor current
1. Priming problem
a. Use a garden hose to fill the Cell at the wall
fitting discharge outlet to push air out of the
Cell. Let water run at medium pressure for 30
seconds.
2. Cell wire disconnected
a. Check all wire connections to ensure that all
are tightly connected.
=
4 hour limit for Usage Sense
1.) Denoted by two horizontal bars.
2.) The Usage Sense signal has been active for more
than 4 hours due to the booster being left on.
3.) Reset BiO2 by pressing the
SET LEVEL
and
BLAST
buttons simultaneously until an
"r"
is seen in the
LED display window,
release buttons.
4.) Usage Sense is improperly wired (Call Dealer).
a. 120 VAC power supply connected to 240 VAC high
speed pump
b. Replace 120 VAC with a 240 VAC BiO2 Control Box.