350
450-
600
1
2
2
2
3
3
3
600-
750
1
1
2
2
2
2
3
750-
900
1
1
1
1
2
2
2
900-
1,100
1
1
1
1
1
1
2
2.) If it is flashing -
a. The salt level is high, check with Salt Test Strips.
b. Sodium chloride level should be 1,200-1,500 ppm.
c. Drain partially and refill with fresh water.
d. Recheck the sodium chloride level.
TROUBLESHOOTING
FAULT CODES (Flashing service light)
FAULT
CODE
DESCRIPTION/RECOMMENDATIONS
J
Low Cell Current
1. Check Cu (Cell Voltage) and Cc (Cell Current)
value in Diagnostics,
"t"
2. If Cu is below 13 call for service. If Cu is 13
to 17 then check Cc.
3. If Cc is below 0.9...
a. Test salt level with Salt Test Strips. If salt
is below 1200 ppm...
b. Add sodium bromide and non-iodized table salt