(sodium chloride). See page 11.
c. Press
BLAST
and see if BiO2 remains on without
the service code reappearing .
d. 240 VAC BiO2 unit may be wired on a 120 VAC
circuit.
e. If
J
code reappears there is a possible
electrode failure. Call for service.
C
Low Motor Current
1. Check for loose motor wire connections (red or
black) at the Cell.
a. Inspect and reconnect
b. Inspect connection at Power Supply and
reconnect.
c. Press
BLAST
. If
"C"
reappears.
2. Possible Air Lock in the Cell.
a. Use a garden hose to fill the cell at the wall
fitting discharge outlet to push air out of the
cell (Let water run at medium pressure for 30
seconds)
b. Press BLAST. If
AA
C
@@
reappears call for service.
3. Cell cable may not be connected at the BiO2
Power Supply.
F
Very Low Cell Current
1. Has sodium bromide and non-iodized table salt
(sodium chloride) been added to the water? If yes
2. Cell may not be receiving water. Make sure water
level covers the BiO2 wall fitting. If OK then
3. Possible air lock in the Cell.
a. Use a garden hose to fill the Cell at the wall
fitting discharge outlet to push air out of the
Cell. Let water run at medium pressure for 30