LED window release the buttons.

TOUCH CONTROL INDICATOR LIGHTS

LED WINDOW

:

Shows the level of maintenance sanitizing. A service code will
be displayed in case of a problem. The letter 

U

 will appear to

indicate Usage Sense (activation of BiO2 when the jet pump is
on) if so equipped.

READY

: When light is on: BiO2 has power.

CELL ON

: When light is on: BiO2 is producing sanitizers.

CHECK SALT

:

Flashing light: Salt level is high, test salt level and
adjust.

Steady light: Salt level is too low: add sodium bromide and
non-iodized table salt (sodium chloride). Please refer to page
(11) of this manual.

SERVICE

: When light is on: check the LED window for a service

code. Contact dealer or BiO2 Help Desk 1-800-516-4028. Please
refer to page (8) of this manual.

OPERATING BiO2

With this basic understanding of the BiO2 Components and their
function, let

=

s discuss how to operate the unit.

STEP 1. GETTING STARTED

1.

Drain your spa and start with fresh water

. Follow your

dealer's recommendations for start up. Adjust the pH to
between 7.2 and 7.8.

2.

Add sodium bromide and non-iodized table salt (sodium

chloride) to your spa water as follows

. Add 58 grams of

sodium bromide (scheduled or registered, for use in spas,
under the Pest Control Products Act) and 454 grams of
non-iodized table salt (sodium chloride) for every 378.5
litres (83.3 imp gal) of water in your spa. This special
combination of sodium bromide and sodium chloride will
dissolve rapidly. Turning on the spa's jets will help
dissolve the sodium bromide and sodium chloride.

Summary of Contents for BIO2 101-PS-C

Page 1: ...s A return to minimum of 3 ppm bromine Recovery time may be reduced by adding a shock compound to the water CERTIFIED TO COMPLY WITH THE LIMITS FOR A CLASS B COMPUTING DEVICE PURSUANT TO SUBPART J OF...

Page 2: ...CE PURSUANT TO SUBPART J OF PART 15 OF THE FCC RULES MODEL 201 PS C INPUT 240 VAC 3 Amps 50 60 Hz OUTPUT 20 VDC 3 5 Amps EPA Est NO 69439 NV 001 US REG NO 24694 PEST CONTROL PRODUCTS ACT PATENT No 5 5...

Page 3: ...there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turnin...

Page 4: ...t without the prior written consent of BioQuest Inc Disclaimer BioQuest Inc has reviewed this manual thoroughly in order that it be an easy guide to your BiO2 sanitizing system All statements technica...

Page 5: ...generates the powerful sanitizing agents oxygen and bromine The water with sanitizers re enters the spa from the cell at about 3 7 litres per minute through the wall fitting Power supply This unit con...

Page 6: ...tact dealer or BiO2 Help Desk 1 800 516 4028 Please refer to page 8 of this manual OPERATING BiO2 With this basic understanding of the BiO2 Components and their function let s discuss how to operate t...

Page 7: ...ge recommended by NSPI National Spa and Pool Institute for safe water During the BLAST cycle a rotating bar will appear on the LED display and the CELL ON LED will be lit The BLAST cycle may be deacti...

Page 8: ...BiO2 has to work 2 The amount of use your spa will get The more the spa is used the greater the number of contaminants enter the water and the harder BiO2 has to work If your spa use is occasional or...

Page 9: ...ense mode for 2 hours after spa use and then will return to the Maintenance Mode If your BiO2 system is not equipped with Usage Sense simply push the BLAST button as you enter the spa This effectively...

Page 10: ...ter in your area is hard high levels of calcium BiO2 may deposit some white flakes on the floor of the spa This is normal BiO2 is actually removing hardness from the spa water This process can continu...

Page 11: ...taneously Keep both buttons pressed until a t appears see illustration below then release the buttons A sequence of letters and numbers will be displayed one digit at a time that will indicate how the...

Page 12: ...n 3 and 5 ppm b Press the BLAST button if the bromine level is below 2 6 Check the diagnostics t a Press both buttons SET LEVEL BLAST simultaneously until a t is seen in the display window and immedia...

Page 13: ...has been performed properly a Test strips require a 1 second dip to read the pH and Alkalinity levels and then a second dip for 30 second to read the Bromine level b Liquid Test Kits OTO DPD require...

Page 14: ...Is the spa filter clean 7 If BiO2 unit is equipped with Usage Sense press the BLAST button for a boost in the sanitizer level I can t adjust the display 1 Lockout function may be enabled a To disable...

Page 15: ...uring the cleaning cycle comes on for every 3 hours of operating time scale may be deposited into the spa water Stain and scale inhibitor may be used The Check Salt Light is on 1 If it is steady a The...

Page 16: ...refill with fresh water d Recheck the sodium chloride level TROUBLESHOOTING FAULT CODES Flashing service light FAULT CODE DESCRIPTION RECOMMENDATIONS J Low Cell Current 1 Check Cu Cell Voltage and Cc...

Page 17: ...e Cell a Use a garden hose to fill the cell at the wall fitting discharge outlet to push air out of the cell Let water run at medium pressure for 30 seconds b Press BLAST If A AC reappears call for se...

Page 18: ...l Let water run at medium pressure for 30 seconds 2 Cell wire disconnected a Check all wire connections to ensure that all are tightly connected 4 hour limit for Usage Sense 1 Denoted by two horizonta...

Page 19: ...BioQuest help desk for further assistance This label transcript service is offered by the Pest Management Regulatory Agency to provide efficient searching for label information This service and this i...

Reviews: