background image

1

3308120.XXX GENESIS AIR FILTRATION SYSTEM

INSTALLATION  AND OPERATING

INSTRUCTIONS

REVISION
Form No. 3308129.026 5/03
(Replaces 3308129.018)
(French 3308134.026)
©2003 Dometic Corporation
LaGrange, IN  46761

USA
SERVICE OFFICE
Dometic Corp.
509 So. Poplar St.
LaGrange, IN 46761
260-463-4858

CANADA
Dometic Dist.
866 Langs Dr.
Cambridge, Ontario
CANADA N3H 2N7
519-653-4390

For Service Center
Assistance Call:
800-544-4881

3308120.XXX

GENESIS AIR FILTRATION SYSTEM

FOR

57XXX SERIES
59XXX SERIES

600XXX SERIES
620XXX SERIES
630XXX SERIES

AIR CONDITIONERS & HEAT PUMPS

USED WITH

3109226.005 ELECTRONIC CONTROL KIT
3109407.001 ELECTRONIC CONTROL KIT

3107541.009 ANALOG CONTROL KIT
3107541.017 ANALOG CONTROL KIT
3107546.008 ANALOG CONTROL KIT

Important: 

These instructions

must stay with unit.
Owner read carefully.

MODEL

3308120.XXX

GENESIS

AIR FILTRATION

SYSTEM

Summary of Contents for GENESIS 3308120.XXX

Page 1: ...dge Ontario CANADA N3H 2N7 519 653 4390 For Service Center Assistance Call 800 544 4881 3308120 XXX GENESIS AIR FILTRATION SYSTEM FOR 57XXX SERIES 59XXX SERIES 600XXX SERIES 620XXX SERIES 630XXX SERIES AIR CONDITIONERS HEAT PUMPS USED WITH 3109226 005 ELECTRONIC CONTROL KIT 3109407 001 ELECTRONIC CONTROL KIT 3107541 009 ANALOG CONTROL KIT 3107541 017 ANALOG CONTROL KIT 3107546 008 ANALOG CONTROL K...

Page 2: ...2 3308120 XXX GENESIS AIR FILTRATION SYSTEM NOTES ...

Page 3: ...cessorieslikeA Eoutdoorpatioandwindowawnings willreduceheatgainbyremovingthedirectexposureto the sun They also add a nice area to enjoy company during the cool of the evening C Condensation Note The manufacturer of this Genesis Air Filtration System will not be responsible for damage caused by condensed moisture on ceilings or other surfaces Air contains moisture and this moisture tends to condens...

Page 4: ...rconditioner two thirdsfromfrontofRVandcentered from side to side It is preferred that the air conditioner heat pump be installed in a relatively flat and level roof sectionmeasuredwiththeRVparkedonalevelsurface Improper installation may damage equip ment could endanger life cause serious in jury and or property damage WARNING 3 AIR DISTRIBUTION SYSTEM SIZING DESIGN The Installer of this air condi...

Page 5: ...ns packaged with the system options before beginning the installation B ROOFANDCEILINGOPENINGPREPARATION 1 A 14 1 4 x 14 1 4 1 8 opening must be cut through the roof and ceiling of the RV This opening must be located between the roof and reinforcing members C DUCTSIZINGREQUIREMENTSASFOLLOWS NOTE Duct sizes listed are inside dimensions Min Max 1 Duct Depth 2 00 2 1 2 2 Duct Width 8 00 10 00 3 Total...

Page 6: ...will damage the roof gasket Note If center duct system is being used be sure to installductadaptertothebottomofthebasepan before unitisplacedoveropening Ductadapter3100342 XXX and 3100262 XXX can be used Alternate methods of duct connection are available for installation however they must be approved in writing by Dometic C Locate the foam divider and insert it corner to corner in the 14 1 4 x 14 ...

Page 7: ...peoffofthedividerandplace it on the center of the rear edge of return air opening on the ceiling template See figure 7 FIG 8B Penguin Models Lay Control Box Flat On Top Of Ceiling Template Control Box Two Screws Vehicle Front FIG 8A Brisk Air Models Mount Control Box on Edge To The Flange on Ceiling Template Control Box Three Screws Vehicle Front FIG 7 Foam Divider Ceiling Template Center And Stic...

Page 8: ... from the supply control box and filter indicator See figure 9 Note Number 10 cabinet screw can be used to replace the two front screws and pull the plastic return air cover to the ceiling when the ceiling material is hard 1 If solar panel is installed see instructions pack aged with solar panel option I Tighten the screws holding the return air cover Slide the filter from the right side looking t...