knob must be pressed for 15 seconds after the flame has lit. If the pilot does not light, repeat
the procedure.
For new installations or when the cylinder is changed, it may be difficult to light the pilot flame: it
does not remain attached to the collar of the pilot but tends to escape and goes out when the valve knob
is released. Repeat the lighting procedure a few times until turbulence (cause of the inconvenience) is
removed, the pilot flame will remain attached to the collar and alight, and the burner will start.
3.
Regulating the heat:
a.
For “minimum” position, press the knob down hard and turn anti-clockwise to the position
marked “
“ (see fig. “pos.1”).
b.
For “medium” position, press the knob part and turn anti-clockwise to the position marked
“
“ (see fig. “pos.2”).
c.
For “maximum” heat, press the knob down hard and turn anti-clockwise to the position
marked “
“ (see fig. “pos.3”).
e)
To return to medium and minimum settings, press the knob and turn clockwise until reaching
the position required.
5. To switch off the stove, press the knob and turn clockwise until reaching the OFF position
marked “OFF”: To switch the stove off completely, the cylinder valve must always be shut.
Never move the stove when it is working.
CLEANING AND MAINTENANCE
Attention: before cleaning the appliance, turn it off and wait for it to cool completely.
To clean the outside of the heater, use a soft cloth soaked with water and a liquid detergent. Do not
use scouring pads or abrasive products.
Do not use water, inflammable or abrasive cleaners.
•
Regularly inspect the atmosphere analyzer and the aeration holes; if there is dust or lint, remove it
without damaging the burner or tubing.
•
Regularly check the condition of the flexible rubber tube and replace it by the expiration date
stamped on it; check the condition of the gasket seal on the pressure regulator every time the gas
cylinder is changed.
•
Take care not to hit or damage the surface of the burner (it's delicate), the fittings and gas tubes, the
tap and all the other components of the gas circuit.
•
We recommend that you have the heater inspected once a year by one of our authorized service
centers.
•
If you decide not to use the heater for an extended period, it is a good idea to follow the
instructions below:
Close the tap on the cylinder and disconnect the pressure regulator from the cylinder.
1)
Store the cylinder in a well-ventilated room, far from inflammable or explosive materials and
preferably outside your home; never store the cylinder in a basement or attic.
Pos.A
Position lighting
Pos.1
Position Minium
Pos.2
Position medium
Pos.3
Position
maximum
Pos.OFF
Position Off
Summary of Contents for K80.NE