78
FLYNET 100
Input Register (Op.code = 04) (Read-only)
Variable
Type
Register
Notes
Scale
Gross weight
Float
1-2
Net weight
Float
3-4
Tare
Float
5-6
Max capacity
Float
7-8
Division
Float
9-10
Gross weight (high resolution)
Float
11-12
Only if non-legal indicator
Net weight (high resolution)
Float
13-14
Only if non-legal indicator
Scale status
Int
15
Stable weight
Boolean
16
Zero
Boolean
17
Minimum weighing
Boolean
18
Underload
Boolean
19
Overload
Boolean
20
Alibi memory commands
Alibi memory status
Int
30
Only if alibi memory is enabled with a licence
Alibi memory code
Long
31-32
Only if alibi memory is enabled with a licence
Alibi memory gross weight
Float
33-34
Only if alibi memory is enabled with a licence
Alibi memory net weight
Float
35-36
Only if alibi memory is enabled with a licence
Alibi memory tare
Float
37-38
Only if alibi memory is enabled with a licence
Alibi memory Tare P1
Float
39-40
Only if alibi memory is enabled with a licence
Alibi memory Tare P2
Float
41-42
Only if alibi memory is enabled with a licence
Holding Register (Op.code = 03 - 06 - 16) (Read-write)
Variable
Type
Register
Notes
Tare
Float
1-2
Only if enabled
Tare P1
Float
3-4
Only if enabled
Tare P2
Float
5-6
Only if enabled
Selected scale
Int
10
Coil (Op.code = 01 - 05 - 15) (Read-write)
Variable
Type
Register
Notes
Reset scale
Command 1
Self-weighted tare
Command 2
Delete tare
Command 3
Execute alibi memory weighing Command 20
Only if alibi memory is enabled with a licence
Input/Output
Output 01
Read write 1001
Output 02
Read write 1002
Optional outputs
Read write 1101...11xx
Slot1
Summary of Contents for FLYNET 100
Page 2: ......
Page 112: ...110 FLYNET 100 ...
Page 121: ...119 FLYNET 100 10 12 Assembling disassembling the HDMI port ...