12
ELECTRICAL
2 - TECHNICAL SPECIFICATIONS
2.3 Electrical Specifications
z
NOTE:
Unit Rated kVA = rated Voltage x rated Current x 1.732
1000
Input Voltage
115V Models: 115 Vac 1 phase, +/– 10%
230V Models: 200-230 Vac, 3 phase, +/– 15%
460V Models: 380-460 Vac, 3 phase, +/– 15%
600V Models: 600 Vac, 3 phase, +10 – 15%
Line Frequency
50 / 60Hz ± 2Hz
Source kVA (max)
10 times the unit rated kVA (see Note below)
DC Bus Voltage for:
Overvoltage Trip
Dynamic Brake Activation
Nominal Undervoltage (UV) Trip
115VAC Models 230 VAC Models 460VAC Models 600VAC Models
406VDC 406VDC 814VDC
1017VDC
388VDC 388VDC 776VDC
970VDC
199VDC 199VDC 397VDC 497VDC
Control System
V/Hz or SVC
Carrier frequency = 1 – 16 kHZ, programmable
8kHz max. for 125-200HP
Output Voltage
0 to 100% of line voltage, 3 phase
Overload Capacity
120% of rated normal duty rms current for 60 seconds
150% of rated heavy duty rms current for 60 seconds
Frequency range
0.1 to 400 Hz
Frequency stability
0.1 Hz (digital), 0.1% (analog) over 24 hours +/– 10 C
Frequency setting
By keypad or by external signal
(Speed Pot 0 to 5VDC; 0 to 10VDC; 0 to 20mA, or 4 to 20mA)
OR by pulse train up to 100 kHz
Summary of Contents for RSi S4 Series
Page 4: ......
Page 9: ...1 1 Introduction...
Page 16: ...8 1 INTRODUCTION NOTES...
Page 17: ...9 2 Technical Specifications...
Page 28: ...20 2 TECHNICAL SPECIFICATIONS NOTES...
Page 29: ...21 3 Installation...
Page 37: ...29 4 Connections...
Page 51: ...43 4 CONNECTIONS 4 5 2 S4 Wiring Diagram S4 Series Wiring Diagram...
Page 56: ...48 4 CONNECTIONS NOTES...
Page 57: ...49 5 Keypad Operation and Programming...
Page 70: ...62 NOTES 5 KEYPAD OPERATION AND PROGRAMMING...
Page 71: ...63 6 Parameter Groups...
Page 82: ...74 NOTES 6 S4 Parameter Groups...
Page 83: ...75 7 Parameter Descriptions...
Page 149: ...141 8 Troubleshooting Maintenance...
Page 159: ...151 9 Motor Characteristics...
Page 162: ...154 9 MOTOR CHARACTERISTICS NOTES...
Page 163: ...155 10 Options...
Page 165: ...157 11 Appendices...