150
8 - TROUBLESHOOTING & MAINTENANCE
z
NOTE: Shaded faults are auto-resettable, except where noted
.
30
Param Range
Parameter out of
range
0
One of the customer parameters
is out of range
- Reset parameters to factory
default
- Consult factory
31
Pwr Wiring
Power wiring error
0
This fault flags a problem with
the drive wiring
- Check that input power wiring
is not connected to load power
terminals
- Consult factory
1
This fault can occur if an IOC
fault is detected during the power
wiring test
32
Low Voltage
Low voltage trip
0
This fault occurs if a power dip
occurs when the drive is
operating, and the drive is not
able to ride through the power
dip before shutting off outputs
- Verify that input line power is
within the drive’s specifications
- Add a transformer or reduce
demands to power feed
- Increase line capacity
- Exchange magnetic switch.
- Consult factory
33
1Ph Overload
1Ph overload
0
If the user configures parameter
AFN 28
for single-phase
operation, this fault occurs if the
bus voltage ripple is outside the
limit of the drive
- Check that input power
demand does not exceed the
drive’s capacity for single-phase
operation
- Consult factory
34
RS Meas. Fail
Stator resistance
measurement failed
0
If the drive cannot measure the
stator resistance properly, this
fault occurs
- Try the routine again and if the
fault occurs twice, consult the
factory
35
Fan Loss
Loss of fan control or
operation
0
There is a problem with the heat
sink fan
- Consult Factory
1
There is a problem with the
internal fan. This occurs only on
Size 4 and 5 models. All other
models display a fan error
warning.
Note that this is a lack of fan
control, so the fan can be
spinning and this fault will still
occur. This can happen if the fan
is on and should not be, or if the
fan feedback signals are
obstructed from getting to the
control board.
Summary of Contents for RSi S4 Series
Page 4: ......
Page 9: ...1 1 Introduction...
Page 16: ...8 1 INTRODUCTION NOTES...
Page 17: ...9 2 Technical Specifications...
Page 28: ...20 2 TECHNICAL SPECIFICATIONS NOTES...
Page 29: ...21 3 Installation...
Page 37: ...29 4 Connections...
Page 51: ...43 4 CONNECTIONS 4 5 2 S4 Wiring Diagram S4 Series Wiring Diagram...
Page 56: ...48 4 CONNECTIONS NOTES...
Page 57: ...49 5 Keypad Operation and Programming...
Page 70: ...62 NOTES 5 KEYPAD OPERATION AND PROGRAMMING...
Page 71: ...63 6 Parameter Groups...
Page 82: ...74 NOTES 6 S4 Parameter Groups...
Page 83: ...75 7 Parameter Descriptions...
Page 149: ...141 8 Troubleshooting Maintenance...
Page 159: ...151 9 Motor Characteristics...
Page 162: ...154 9 MOTOR CHARACTERISTICS NOTES...
Page 163: ...155 10 Options...
Page 165: ...157 11 Appendices...