Parameter List
5.1
Drive Group
48
5 - Parameter List
CODE
Parameter Name
Keypad
Display
Setting Range
Factory
Default
Adj.
during
run
Page
DRV-00 Frequency command
0.00
0-400 [Hz]
0.00
Yes
58
DRV-01 Acceleration Time
ACC
0-6000 [sec]
5.0 [sec]
Yes
58
DRV-02 Deceleration Time
dEC
0-6000 [sec]
10.0 [sec]
Yes
58
DRV-03
Drive Mode
(Run/Stop method)
drv
0 (Keypad)
1 (Fx/Rx-1)
2 (Fx/Rx-2)
3 (RS485)
1
(Fx/Rx-1)
No
59
DRV-04
Frequency Mode
(Freq. setting method)
Frq
0 (Keypad-1)
1 (Keypad-2)
2 (V1 1)
3 (V1 2)
4 (Term. I)
5 (Term.V1 1 +
Term.I) 6
(Term.V1 2 +
Term. I)
7 (RS485)
0
No
60
DRV-05 Step Frequency 1
Stl
0-400 [Hz]
10.00 [Hz]
Yes
61
DRV-06 Step Frequency 2
St2
20.00 [Hz]
DRV-07 Step Frequency 3
St3
30.00 [Hz]
DRV-08 Output Current
CUr
*[A]
-[A]
-
62
DRV-09 Motor RPM
rPM
*[rpm]
-[rpm]
-
62
DRV-10 DC link Voltage
dCL
*[V]
-[V]
-
62
DRV-11 User Display Selection
vOL
vOL
Por
tOr
vOL
-
62
DRV-12 Fault Display
nOn
-
None nOn
-
63
DRV-13 Motor Direction Set
drC
F (Forward)
r (Reverse)
F
Yes
63
DRV-14 Drive Mode 2
drv2
1
0-2
1
No
64
DRV-15
Frequency Mode
(Freq. setting method 2)
Frq2
0-6
0
No
64
1
Only displayed when one of the multi-function input terminals 1-8 [I17-I24] is set to "22".
Summary of Contents for RSi GX Series
Page 7: ...1 Introduction 1...
Page 15: ...2 Technical Specifications 9...
Page 24: ...Notes 18 2 TECHNICAL SPECIFICATIONS...
Page 25: ...3 Receiving and Installation 19...
Page 41: ...4 Operation 35...
Page 53: ...5 Parameter List 47...
Page 62: ...Notes 56 5 Parameter List...
Page 63: ...6 Parameter Descriptions 57...
Page 135: ...7 Remote Communication 129...
Page 149: ...8 Troubleshooting Maintenance 143...
Page 162: ...Notes 156 8 Troubleshooting Maintenance...
Page 163: ...9 Options 157...
Page 165: ...10 Appendices 159...