H71: Accel/Decel Time Scale
Range:
0-2 (Default: 1)
Description:
This is used to change the resolution for the acceleration and deceleration
times.
H72: Power on Display
Range:
0 - 13 (Default: 0)
Description:
This parameter selects the first parameter to be displayed on the keypad
when the input power is first applied.
102
6 - Parameter Descriptions
Output freq
Accel time
Decel time
Max freq
H70: Max. Freq
Certain freq
Accel time
Decel time
Next target freq
H70: Delta Freq
Display
Description
Display
Description
0
Frequency command (0.00)
7
Multi-Step frequency 3
1
Accel time (ACC)
8
Output current (CUr)
2
Decel time (DEC)
9
Motor rpm (rPM)
3
Drive mode (drv)
10
Inverter DC link voltage
(dCL)
4
Frequency mode (Frq)
11
User display select (vOL)
5
Multi-Step frequency 1
12
Fault display 1
6
Multi-Step frequency 2
13
Operating direction select
Setting Range
Description
Display
Select
0
0.01 sec.
The Accel/Decel time is changed by 0.01 sec./10msec.
The maximum setting range is 60 seconds.
1
0.1 sec.
The Aceel/Decel time is changed by 0.1 sec./100 msec.
The maximum setting range is 600 seconds.
2
1 sec.
The Accel/Decel time is changed by 1 second. The
maximum setting range is 6000 seconds.
Summary of Contents for RSi GX Series
Page 7: ...1 Introduction 1...
Page 15: ...2 Technical Specifications 9...
Page 24: ...Notes 18 2 TECHNICAL SPECIFICATIONS...
Page 25: ...3 Receiving and Installation 19...
Page 41: ...4 Operation 35...
Page 53: ...5 Parameter List 47...
Page 62: ...Notes 56 5 Parameter List...
Page 63: ...6 Parameter Descriptions 57...
Page 135: ...7 Remote Communication 129...
Page 149: ...8 Troubleshooting Maintenance 143...
Page 162: ...Notes 156 8 Troubleshooting Maintenance...
Page 163: ...9 Options 157...
Page 165: ...10 Appendices 159...