SYSTEM INSTALLATION MANUAL
89000016
Table 8008. WiFi Module DO-160G Environmental Qualifications (Cont)
Environmental Test
Section
Category
Compliance
Method
Magnetic effect
15
NA
X
Power input
16
B
T
Voltage spike
17
NA
X
Audio frequency conducted susceptibility -
Power inputs
18
NA
X
Induced signal susceptibility
19
NA
X
Radio frequency susceptibility
20
NA
X
Emission of radio frequency energy
21
MM
3
T
Lightning, induced transient susceptibility
22
A3XXXX
T
Lightning direct effects
23
NA
X
4
Icing
24
NA
X
4
Electrostatic discharge
25
NA
X
Fire, flammability
26
NA
X
Compliance method key:
T = Test
X = No testing required/no credit requested
NA = Not applicable
NOTES:
1
D: Altitude at +50,000 feet (+15.24 km).
A: Overpressure at
15,000 feet ( 4.57 km) and decompression at +50,000 feet (+15.24 km).
2
EUT does not require cooling for correct operation.
3
Exception at 2.4 GHz as the system transmits at that frequency.
4
Required for other equipment (the antenna) only, not for the EUT.
4.
Typical Interconnect Diagram
A.
KGX and WiFi Module Interconnect Diagram
(1)
Refer to Figure 8007 for a typical KGX and WiFi module interconnect diagram.
EFFECTIVITY
ALL
Page 8009
22 Dec 2016
© Honeywell International Inc. Do not copy without express permission of Honeywell.