SYSTEM INSTALLATION MANUAL
89000016
Figure 3058. (Sheet 1 of 1) Serial OUT Channel X Line Speed Display
(12) ARINC IN Channel X Data Type
NOTE:
X = Channel number.
(a)
The KGX can receive data through two ARINC 429 input channels. The following options
are offered for selecting ARINC 429 input type for each individual channel of the KGX:
• Not used
• GPS
• Air data computer
• AHRS
• ADC+AHRS
• Txpdr Control
• Other 1
• Other 2.
NOTE:
Refer to Paragraph 3.C. Step (4) in the CONFIGURATION, CALIBRATION,
AND CHECKOUT section for information on selecting ARINC input settings.
(b)
The display screen is as shown in Figure 3059 with one of the options from above.
(c)
Rotate the CODE knob either clockwise or counterclockwise to display the options above
and select the correct ARINC input type. Once selected, press the ENT key to confirm
your selection and move to the next configuration item in the configuration mode.
NOTE:
If “Not Used” is selected then the ARINC input line speed configuration mode
will not be displayed and the next configuration mode item will be displayed.
Figure 3059. (Sheet 1 of 1) ARINC IN Channel X Data Type Display
(13) ARINC IN Channel X Interface Speed
NOTE:
X = Channel number.
(a)
The following options are offered for selecting the ARINC interface speed for each
channel data type:
• Low
• High.
(b)
The display screen is as shown in Figure 3060 with one of the options from above.
EFFECTIVITY
ALL
Page 3049
22 Dec 2016
© Honeywell International Inc. Do not copy without express permission of Honeywell.