Figure 38. Replacing the Glass Flat
7. Insert the glass flat into the left end first, pressing down against the spring and guiding
the tip about 1/2” into the machine. This enables the other end of the glass to swing
down and rest easily into the groove.
8. Slide the exposed tip 1/4” into its socket. The springs will press the glass flat against
the holder surface. Slide the glass left and right to feel if it is centered and seated.
9. Using the optic cleaning pad, (Maintenance Kit Item #5) carefully clean the exposed
surface of the glass. Inspect the glass flat after cleaning to ensure all dust and residue
have been removed.
10. Close the transport firmly.
6.4
Cleaning the Skimmer Rollers
As the skimmer rollers become dirty, they may begin to slip on the paper or cause multi-
feeds. To prevent feeding problems, clean the skimmer rollers once a day or as needed.
NOTE:
Types and condition of the documents being scanned may require more frequent
cleanings.
Take the following steps to clean the skimmer rollers:
1. Remove all documents from the feeder and exit tray.
2. Using the front panel buttons, press the CLEAR button to put the scanner in READY
mode.
3. Press the CLEANING MENU key on the front panel.
4. Press the F1 key to start the scanner.