5.2.2.6 Blinking Bulb Icon
If you see this display on the control panel menu (
), the lamps are wearing out. Place
an order for new lamps from Bell & Howell by using the Reorder Fax Sheet included on
the 8000 Plus CD or by visiting our online store at
www.bellhowell.imagingcomponents.com
.
You may continue scanning even though this message is displayed, however failure to
replace the lamps may affect image quality.
Refer to Section 6.8,
Cleaning and Replacing the Lamps
of this manual to replace the
lamps.
5.2.2.7 DOOR OPEN
The side access panel and the transport must be closed before operating the scanner. The
control panel warns you if the side door or the transport are open. The side access panel
cannot close unless the transport is open. Take the following steps to secure the scanner:
1. Open the transport.
2. Close the side access panel located on the left side of the scanner.
3. Close the transport.
4. Resume scanning.
5.3
Normal Operating Routine
Normal scanner operation includes the following:
•
Initializing the scanner
•
Setting various scanner parameters
•
Scanning documents
5.3.1 Initializing the Scanner
When you apply power to the scanner, it goes through a short initialization sequence.
When the scanner has finished initializing, the LCD displays the READY message. If you
have purchased a SCSI scanner, the workstation should be powered up only after the
scanner is powered up.
5.3.2 Document
Preparation
Organize the documents to be scanned in an orderly stack. Use the guidelines in the
following subsections to prepare the documents for scanning.