Release Notes
the NVISION router configuration in XEdit, the first change made to the router
configuration in NV9000-SE Utilities may not be reflected on the monitor wall (i.e., the
corresponding text label may momentarily fail to be updated).
•
[Ref. #30764]
Logical sources:
In XEdit, after changing the name of a level in the sources
table, the
Save
button (and the corresponding element on the
File
menu) may remain
unavailable.
•
[Ref. #32805]
Kaleido-IP and EdgeVision:
Input signals with a resolution higher than
960 × 540, from an EdgeVision system, are not yet supported.
•
[Ref. #31020/32129]
Kaleido-IP:
In the case of a Kaleido-IP, when monitoring a film-based
signal (subjected to 3:2 pulldown deinterlacing) you may notice ghosting artifacts on
the monitor wall.
•
[Ref. #33257]
Kaleido-IP:
In the case of a Kaleido-IP, when using the incremental copy
tool to populate a
video
level in XEdit’s logical sources table, the auto-increment is
momentarily limited to programs within the current transport stream.
•
[Ref. #33279]
Kaleido-IP:
After a program was removed from a transport stream and then
added back to it, corresponding video windows may remain blank on the monitor wall.
•
[Ref. #33619]
Multi-program transport streams and Kaleido-IP:
In the case of multi-
program transport streams (MPTS) sources where programs are added or removed
dynamically (e.g., when re-grooming or channel-lineup changes are taking place), it
may happen that video and audio programs are shifted in the Kaleido-IP sources table,
resulting in incorrect video and audio on the monitor wall.
Known Issues and Limitations
Installation, Upgrade, Downgrade, Live Update
All Multi-Viewer Models
•
[Ref. #33692]
Cluster and cascade systems:
All members of a cascade or cluster must
have the same version of the Kaleido-X software.
Note:
If your Kaleido-IP multi-viewer shipped with a version of the
Kaleido-X software earlier than 6.30, you may still have the problem
described above, even after upgrading your system to version 6.30 (or later),
in which case please contact Technical Support for a solution.
Note:
The star (
) symbol indicates a new known issue or limitation found
in Kaleido-X version 6.51.
Note:
Although some Kaleido-X version combinations may prove to be
compatible in the context of a cluster or cascade system, this is not
supported. If you upgrade any cluster or cascade member from Kaleido-X
version 6.30 or earlier
to version 6.40 or later
make sure you upgrade all
members to the same version. Failure to do so may result in erratic mouse
pointer behavior on the monitor wall.