36
Release Notes
Known Issues and Limitations
default). If you must configure more than one TSL (network) device make sure to
specify different port numbers (in the 1023–65,535 range) to avoid conflicts.
•
[Ref. #26889]
On rare occasions, switching from online to offline mode, or vice versa,
while the
System
tab is active may result in most of the panels in XEdit displaying a
“Loading...”
message indefinitely.
Workaround:
Click a tab other than
System
, in the main tab bar (e.g.,
Rooms
,
Layouts
,
etc.), and then:
• If you just switched to
offline
mode, connect to the multi-viewer, and then switch
back to offline mode.
• If you just switched to
online
mode, close the connection to the multi-viewer, and
then switch back to online mode.
Alternatively, close XEdit and then open it again.
•
[Ref. #25692/26582]
Cannot retrieve backup:
XEdit cannot retrieve a database backup if
the original system from which this backup was made included elements (e.g., actions,
virtual alarms, logical sources, levels) with an ampersand (“&”) in their name. When you
attempt to retrieve such a backup, XEdit becomes unresponsive and you must use
Windows Task Manager to close it. An “Uncaught exception” will appear in
xedit.log
.
•
[Ref. #25545]
Cannot add input cards:
When configuring a Kaleido-X (7RU) or Kaleido-X
(14RU) system, if all input slots are empty while one or more router cards are present in
the System hierarchical list, then it may not be possible to add input cards (or more
router cards) to the system.
Workaround:
Close XEdit and open it again.
•
[Ref. #24910]
Logical Sources:
If you do not click
Save
after deleting a level from the
sources table, then adding a new level may cause unwanted data from the deleted
level to reappear in the table.
Workaround:
After deleting a level from the sources table, click
Save
.
•
[Ref. #24921/26351]
Internal router port aliases not available to logical sources:
Aliases
defined for the physical sources or destinations of a Kaleido-X (7RU) or Kaleido-X16
multi-viewer’s internal router may not be available in the filtered System list associated
with the sources table. Specifically, in the case of the
KX Router
logical router, neither
source nor destination aliases from the physical internal router are available. Source
and destination aliases defined for an external router are always available (regardless of
the logical router).
•
[Ref. #24820]
Online mode:
When connected to a KMV-3901/3911 multi-viewer from
XEdit (in online mode), if you modify the layout that is currently shown on the monitor
wall and then save it, the graphic elements on the monitor wall may freeze for several
seconds until the layout is fully loaded again.
•
[Ref. #24258]
Resetting calibrations to factory defaults:
With the current version of the
Kaleido-X software, the calibration reset feature (see “Restoring Factory Defaults”, in the
Kaleido-X User’s Manual) is not immediately effective on the multi-viewer.
Workaround:
Restart the multi-viewer, close XEdit, and then open it again, for the
calibrations to be applied.
Note:
Database backups created in XEdit version 5.10 and later can be
retrieved without problem. Make sure to create a fresh backup once you
have updated a Kaleido-X system from version 5.00 (or earlier) to version
5.10 or later.