33
Kaleido-X
Release Notes
Kaleido Remote Control Protocol (Gateway)
•
[Ref. #23341]
If the name of a Kaleido-X system contains a space or a special character,
opening a remote control session (gateway) with user context may not be possible.
Workaround:
Remove any space or special character from the system name.
Alternatively, if editing the gateway command is an option, you may try percent-
encoding the unsafe characters in the system name.
•
[Ref. #17997]
If a single
<setKTimer2>
command is used to change both
PresetTime
and
either
TimerMode
or
EndMode
for a timer monitor, the
PresetTime
change is ignored.
Workaround:
Send separate
<setKTimer2>
gateway commands for each parameter that
is to be changed.
XAdmin
•
[Ref. #31094]
Kaleido-IP:
When reinstalling, upgrading, or downgrading the Kaleido-X
software on a Kaleido-IP multi-viewer that has version 6.02 or earlier, once you have
uploaded the RUN package to the unit, clicking the
Upgrade
button more than once
may cause the installation to be repeated, which could result in a defective installation.
•
[Ref. #30291]
100 Mbps half-duplex data interface configuration:
Kaleido-X (7RU, 4RU,
and 14RU) multi-viewers with output cards that shipped with version 5.22 (or later),
initially or after repairs, and Kaleido-X16 multi-viewers that shipped with version 5.22
(or later), initially or after repairs, do not support 100 Mbps half-duplex
communications.
•
[Ref. #18927]
Kaleido-X (4RU) PSU alarms:
When PSU A or B is absent, or turned off,
XAdmin reports a normal status for the associated “AC status”, “DC status”, “temperature
status”, and “vendor ID unknown” alarms, in the
Status and options
page.
•
[Ref. #25577]
KMV-3901/3911 3Gbps signal decoding option:
If you enable the 3Gbps
signal decoding option for a KMV-3901/3911 multi-viewer in XAdmin, while a 3Gbps
source is already connected to your multi-viewer, the option will not be immediately
effective.
Workaround:
Disconnect the 3Gbps source, and then connect it to your multi-viewer
again.
•
[Ref. #19451]
Kaleido-X input options:
In the case of a Kaleido-X (4RU, 7RU, or 14RU)
multi-viewer, if you try enabling or disabling more than one option on the same input
card, once the card has restarted only the first change will persist.
Workaround:
Enable or disable input options one at a time, making sure to reset the card
after each change.
•
[Ref. #25752]
XAdmin momentarily unavailable:
When configuring IP addresses for the
output cards in a Kaleido-X (4RU, 7RU, or 14RU) multi-viewer, if a slave output card is
assigned an invalid IP address, XAdmin may remain unavailable for several minutes
after the multi-viewer has restarted.
•
[Ref. #25309]
Kaleido-X16 status and options:
In the case of a Kaleido-X16 multi-viewer,
you may notice strange values (e.g., serial numbers, voltage or current values reported
as zeroes; aberrant “Mezz”, “PP”, and “PS” temperatures) on the Status and Options
page.
Note:
Once you have upgraded to version 6.20 or later, you will benefit
from a more robust interface.