[Ref. #23763]
Alarm status not updated:
When using XEdit in online mode, having a
firewall enabled on your client PC or laptop may prevent alarm status indicators from
being dynamically updated in XEdit.
Workaround:
Disable the firewall.
•
[Ref. #17289]
Concurrent sessions:
If two or more XEdit sessions are open and connected
to the same multi-viewer in online mode, changes made under the
System
tab and
applied from one XEdit session are not reflected in the others.
•
[Ref. #20108]
Cluster composition not automatically updated across concurrent XEdit
sessions:
if user A adds a multi-viewer to a cluster while user B is connected to a
different member of the same cluster, then the addition is not automatically reflected
in XEdit for user B.
Workaround:
Other concurrent users must close XEdit and open it again to view the
updated cluster composition.
•
[Ref. #23057]
Database location:
If the XEdit database is located in a directory whose
name contains an IP address, then attempting to export the database will cause a
system error and XEdit will close.
Workaround:
Rename the directory without using an IP address.
•
[Ref. #22685/T94343]
Offline changes to logical sources (channels) are not reflected on
the monitor wall after a database export:
If changes are made (in XEdit) to a logical
source currently in use, and if the modified database is then exported to the multi-
viewer, the changes will not appear on the monitor wall, even if the layout is refreshed.
Workaround:
After the database export is completed, create and load an empty layout
(i.e., a layout that does not contain any monitors) on the monitor wall. This will cause the
logical source cache to be emptied. You can then load the layout with recent logical
source changes.
•
[Ref. #14316]
Custom resolutions:
Custom resolutions created in XEdit must have the
same active width and active height as one of the default resolutions, otherwise the
new resolution will not be applied. When creating a new resolution, it is recommended
to start from an existing resolution (i.e., one whose active height and width parameters
match your display), and update the timing parameters as needed. You may have to
reboot twice after adding an unknown resolution (i.e., a resolution whose geometry
[width × height] is not already known by the multi-viewer).
•
[Ref. #22318]
Layout preview missing:
In XEdit version 4.00 and later, if you click
Open
layout
on the
File
menu, you will not see preview images for layouts created prior to
version 4.00. In addition, if you replace the multi-viewer in the System hierarchical list,
then any existing layout previews may become unavailable.
Workaround:
To generate a preview for a layout, open the layout in XEdit, and then save
it.
•
[Ref. #15732]
In the
Actions
tab, the
Undo
and
Redo
commands are not available.
•
[Ref. #15867]
The
Set action
menu is not available when you right-click a GPI line
element in the System hierarchical list in the
System
tab.
Workaround:
(1) Click the
Actions
tab, and expand the GPI/GENLOCK card in the filtered
System list that appears in the
Tools
pane. (2) Right-click the GPI In or GPI Out element
under the GPI line for which you wish to define a background action, point to
Set action
,
and then click the appropriate action type on the shortcut menu.
Alternatively, click the
Channels/Sources
tab, and then click anywhere under an alarm
heading. You can then expand the GPI/GENLOCK card in the filtered System list, and
proceed as described above.