13
Kaleido-X
Release Notes
• publishing signal/service probing alarms to SNMP managers (see Ref. #27416 on
• encrypted stream indicator (see Ref. #29645 on
• cropping and zooming (underscan/overscan)
• spanned monitors
KMV-3901/3911
[Ref. #KX-6295]
KMV-3901/3911 NTP time sourcing:
If the Densité CPU-ETH2 controller
that provides date and time information to a KMV-3901/3911 multiviewer is configured
to obtain this information from an NTP server, you may notice that the time starts
drifting after a few days.
Workaround:
Restart the multiviewer.
•
[Ref. #34788]
KMV-3901/3911 time reference:
In the case of a KMV-3901/3911 multi-
viewer, count down URS time code is not yet supported as a time code reference.
•
[Ref. #30947]
KMV-3911 HD-SDI output activation:
In the case of a KMV-3911 multi-
viewer, after enabling the
SDI monitoring output
option in XAdmin, you may need to
power cycle the multi-viewer for the change to be effective.
•
[Ref. #25435]
KMV-3901/3911 networking setup:
If the Densité CPU-ETH2 controller
associated with a KMV-3901/3911 multi-viewer is configured to apply settings stored in
its non-volatile memory whenever a Densité card is inserted or restarted, then it may
not be possible to change the multi-viewer’s IP address and other networking
parameters.
Workaround:
Before changing the multi-viewer’s networking parameters, make sure the
Densité controller’s
default action
is set to
keep card settings
. Refer to “Step 2: Networking
Setup” in the Kaleido-Modular Quick Start Guide, for detailed instructions.
•
[Ref. #25909]
KMV-3901/3911 auto-recovery not fully supported:
If you replace a KMV-
3901 or KMV-3911 card with a new one (in the same Densité frame slot), the new card
receives appropriate network settings from the Densité controller, but the multi-
viewer’s database is not automatically restored.
Workaround:
Manually restore the database, either
• by using XEdit to export a local copy of the database from your PC or laptop to the
new card, or
• by physically transferring the SD memory card from the old KMV-3901/3911 to the
replacement multi-viewer.
KMV-3901/3911 Limitations
Designed to address production-type applications, the KMV-3901/3911 multi-viewer
models support a subset of the features offered by the other Kaleido-X series models, and
thus may be lacking some of the advanced monitoring capabilities typical of master control
and playout environments. The following Kaleido-X features are
not supported
in the KMV-
3901/3911:
• Alarm probing and metadata extraction:
Note:
The current version of the Densité controller cards do not have
enough non-volatile memory to support full database backups from up to
ten multi-viewer cards.