19
KMX-3921
Installation & Service Manual
KMX-3921-54X4-3+HR Rear Panel
This configuration can be installed only in a Densité 3+ FR4 frame equipped with either a
CPU-ETH3-STD standard or a CPU-ETH3-ADV advanced frame controller. To identify a
Densité 3+ FR4 frame’s controller model, see
How to Identify a Densité 3+ FR4 Frame’s
Multiviewer Capacity Required Multiviewer Cards SFP Module Requirements
36 × 1
4 × KMX-3921-9X1
One single Tx SFP module is required to
support this capacity when displays are
directly connected to the multiviewer’s
rear panel.
36 × 2
4 × KMX-3921-9x2
Two single Tx SFP modules or one dual Tx
SFP module is required to support this
capacity when displays are directly
connected to the multiviewer’s rear panel.
36 × 4
4 × KMX-3921-9x2
Two dual Tx SFP modules are required to
support this capacity when displays are
directly connected to the multiviewer’s
rear panel.
Multiviewer Capacity Required Multiviewer Cards SFP Module Requirements
54 × 1
6 × KMX-3921-9X1
One single Tx SFP module is required to
support this capacity when displays are
directly connected to the multiviewer’s
rear panel.
54 × 2
6 × KMX-3921-9x2
Two single Tx SFP modules or one dual Tx
SFP module is required to support this
capacity when displays are directly
connected to the multiviewer’s rear panel.
54 × 4
6 × KMX-3921-9x2
Two dual Tx SFP modules are required to
support this capacity when displays are
directly connected to the multiviewer’s
rear panel.