10.5
Replacing the float drain
The following requirements must be fulfilled, and preparatory work must be completed before exchanging the float
drain.
Preconditions
Tool
Material
Protective equipment
•
Screwdriver - Philip's head
size 2.5
mm
•
New float drain with enclosed
adapter
•
Protective gloves (liquid-
resistant)
•
Safety glasses with side
protection (goggles)
•
Hearing protection
•
Class FFP 3 respirator
•
Safety shoes
Preparatory work
1.
Open any bypass lines.
Picture
Description
1.
1.
1. Close shut-off valves upstream and downstream of the
filter or the corresponding system section.
2.
2.
Turn knurled screw on the float drain counterclockwise
(left-hand thread) from "
Automatic drainage
" to
"
Mechanically open
".
Automatic drainage
Mechanically open
CLEARPOINT
®