12.2 Disassembly work
The following requirements must be fulfilled to carry out disassembly work and preparatory work must be completed.
Preconditions
Tool
Material
Protective equipment
•
Screwdriver - Philip's head
size 2.5
mm
• No material necessary.
•
Protective gloves (liquid-
resistant)
•
Safety glasses with side
protection (goggles)
•
Hearing protection
•
Class FFP 3 respirator
•
Safety shoes
Preparatory work
1.
Open any bypass lines
Picture
Description
1.
1.
1.
Close the shut-off valves
[1]
upstream and
downstream of the filter or the relevant section of the
system, depressurize the filter and secure the system
against unauthorized pressurization.
2. When using the
BEKOMAT
®
, it must be separated
from the lower part of the filter.
For further information, see the enclosed installation and
operating instructions for the
BEKOMAT
®
.
CLEARPOINT
®
3
eco
coalescing filter
Installation and operation instructions
48 | 60