Beijer Electronics Frequency Inverter BFI-P2
KI00306B 2020-03
www.beijer.se www.beijer.no www.beijer.dk
www.beijerelectronics.com www.beijerelectronics.de www.beijerelektronik.com.tr
27 (31)
Description
Display
range
Explanation
P0-01
1st Analog Input Value
-100 % .. 100 %
100% = max input voltage for Analog input1, Terminal 6
P0-02
2nd Analog Input Value
0 to 100 %
100% = max input voltage for Analog input2, Terminal 10
P0-03
Digital Input Status
00000 to 11111
One digit per input starting with Digital In1 to the left
P0-04
Speed Reference Input
-P1-01 … P1-01
Displayed in Hz if P-10 = 0, otherwise displayed in RPM
P0-05
Torque Controller Reference
0 to 500 %
Displays the set point torque reference input
P0-07
Fieldbus Speed Reference
-P1-01 … P1-01
Displays set point frequency received from Fieldbus interface
P0-08
PID Reference (Setpoint)
0 to 100 %
Displays the setpoint input to the PID controller
P0-09
PID Feedback Level
0 to 100 %
Displays the Feedback input signal to the PID controller
P0-10
PID Controller Output
0 to 100 %
Displays the output level of the PID controller
P0-11
Motor Voltage
0 … 600V AC
Value of RMS voltage applied to motor
P0-12
Output Torque
%
Displays instantaneous output torque level for the motor
P0-13
Trip Log
Displays the four latest fault codes
P0-14
Motor Magnetising Current (Id)
A
Displays motor magnetising current after an auto tune
P0-15
Motor Rotor Current (Iq)
A
Displays motor rotor current after an auto tune
P0-16
DC Bus Voltage Ripple Level
V
Displays the level of ripple present on the DC Bus Voltage.
P0-17
Motor Stator resistance (Rs)
Ω
Displays measured motor stator resistance after an auto tune
P0-18
Motor Stator Inductance (Ls)
H
Displays measured motor stator inductance after an auto tune
P0-19
Motor Rotor Resistance (Rr)
Ω
Displays measured motor rotor resistance after an auto tune
P0-20
DC Bus Voltage
0 … 1000V dc
Internal DC bus voltage
P0-21
Internal Temperature
-20 … 100 °C
Temperature of heatsink in °C
P0-25
Rotor Speed
Hz / rpm
In Vector control mode, displays the estimated rotor speed of the motor or
measured rotor speed with Encoder Feedback
P0-26
kWh meter
0 to 999,9
When overflow P00-27 increases by 1 and reset to 0.
P0-27
MWh meter
0 to 65535
Displays the amount of energy consumed by the drive.
P0-28
Software Version
I/O-version, I/O Checksum, DSP version, DSP checksum.
P0-29
Drive Type
Frame size, Power rating and output phases
P0-30
Drive Serial Number
Unique drive serial number.
P0-31
Total Run Time
hours
Displays the total operating time of the drive.
P0-35
Fan Run Time
0 .. 99999 hours
Displays total operating time of internal cooling fans.
P0-36
DC Bus Voltage at Trip
V DC
Values logged before trip with 8 samples total (256 msec).
P0-37
DC Bus Voltage Ripple at Trip
V DC
Values logged before trip with 8 samples total (20 msec).
P0-38
Heatsink Temperature at Trip
-20 … 100 °C
Values logged before trip with 8 samples total (30 sec).
P0-39
Ambient Temperature at Trip
°C
Values logged before trip with 8 samples total (30 sec).
P0-40
Motor Current Log at Trip
A
Values logged before trip with 8 samples total (256 msec).
P0-41
Over Current Fault Counter
Over Current fault counter
P0-42
Over Voltage Fault Counter
Over Voltage fault counter
P0-43
Under Voltage Fault Counter
Under Voltage fault counter
P0-44
Heatsink Over Temperature
Heatsink Over Temperature fault counter
P0-45
Brake Chopper Short Circuit
Brake Chopper Short Circuit fault counter
P0-46
Ambient Over Temperature
Ambient Over Temperature fault counter
P0-49
Modbus RTU
Modbus RTU communication fault counter
P0-58
Encoder Feedback Speed Value
Hz / rpm
P0-60
Calculated Slip Speed Value (V/F
Mode Only)
%
When slip compensation is enabled using P1-10, the calculated motor slip is
displayed here. The raw value is displayed
P0-64
Switching Frequency
kHz
Displays the actual effective Switching frequency
P0-65
Drive Life Time
Powered up time, hours, min, and sec
P0-70
Option Module ID-code
Identifies Type of Option Module inoption module slot
P0-71
Fieldbus module ID
Fieldbus module Identification Code
P0-74
L1 – L2 Input Voltage
V
Displays the supply voltage measured between L1 and L2 terminals
P0-75
L2 – L3 Input Voltage
V
Displays the supply voltage measured between L2 and L3 terminals
P0-76
L3 – L1 Input Voltage
V
Displays the supply voltage measured between L3 and L1 terminals
P0-77
Encoder Pulse Count (32bit)
pulses
Hi 16-bit and Lo 16-bit
P0-78
Test Parameter ¾
P0-79
Boot Loader/Motor Control version
P0-80
User Defined Internal Parameter
Parameter P6-28 decides value to be shown