Beijer Electronics Frequency Inverter BFI-P2
KI00306B 2020-03
www.beijer.se www.beijer.no www.beijer.dk
www.beijerelectronics.com www.beijerelectronics.de www.beijerelektronik.com.tr
3 (31)
4 Installation
The drive should be mounted in a vertical position only on a flat, flame resistant, vibration free
mounting using the integral holes. IP55/66 is allowed to be mounted outdoors but must be
protected from sunlight and it also recommended having a roof to avoid snow directly on the
drive. BFI will not start if ambient temperature is below minus 10 degrees Celsius.
4.1 Physical dimensions IP66
Rating Drive BFI-P2-IP66
Drive
size
A
Height
[mm]
B
[mm]
D
[mm]
E
[mm]
F
Depth
[mm]
G
Width
[mm]
H
[mm]
I
[mm]
J
[mm]
Weight
[kg]
1 x 230 V
3 x 230 V
3 x 400 V
0043 - 0105
[0,75- 2,2 kW]
0043 - 0105
[0,75- 2,2 kW]
0022 - 0095
[0,75- 4,0 kW]
2
257
220
200
28.5
239
188
176
4.2
8.5
4,8
None
0180
[ 4,0 kW]
0140 - 0180
[5,5 - 7,5 kW]
3
310
277
252
33.4
266
211
198
4.2
8.5
7,7
NOTE
Mounting bolts
Size 2 and Size 3: 4 x M4.
Control Terminal, Required Torque
All Sizes 0,5 Nm.
Power Terminal, Required Torque
All Sizes 1 Nm.
Drive IP-
class and
Size
X [mm]
Above &
Below
Y [mm]
Either
Side
Between
drives
Minimum
Airflow
[m3/min]
IP20, size 2
75
50
0
0,3
IP20, size 3
100
50
0
0,9
IP20, size 4
200
25
70
1,7
IP20, size 5/6
200
25
70
2,9
IP20, size8
250
50
100
14
All IP55 and
IP66
200
10
10
No requirement
Note
All BFI can be mounted close to each