CATASTROPHIC ERRORS
A catastrophic failure is generated each time the AC Power Supply experiences a hardware
failure. Errors are cleared whenever the AC Power Supply transmits a response, except in the
case of a short circuit fault which may only be cleared by cycling power to the AC Supply.
Catastrophic Error Messages
All begin with:
F/0/0ACS/0(DEV):
This message is followed by one explanatory message from the
following text:
OVERTEMP FAULT <cr><lf>
The heat-sink temperature has exceeded its upper limit. The
OVERTEMP LED on the front panel will light.
CURRENT LIMIT FAULT <cr><lf>
SHORT CIRCUIT FAULT: AC SUPPLY <cr><lf>
An output loading fault has occurred causing the supply to exceed
5/0/0% rated current output. The supply automatically shuts down and
opens its output relay. The OVERLOAD LATCH LED on the front
panel will light.
1.6
ADDRESS SELECTION
The GPIB Address for the BL Series Power Supplies is configured via the dip-switch located
on the rear panel. The dip-switch represents the address in binary format. Valid GPIB
Address settings are from 0 to 30. Switch 1 is the LSB, switch 5 is the MSB. Each individual
switch bit is set ('1') when in the 'OFF' position and reset ('0') when in the 'ON' position.
Summary of Contents for BL10000 Series
Page 9: ...3 THIS PAGE BLANK FOR ADDENDUMS ALL MANUAL ADDENDUMS WILL FOLLOW THIS PAGE ...
Page 17: ...11 Figure 3 1 BL10000 AC Source Control Chassis Front and Rear Panel Views ...
Page 49: ...6 1 SECTION 6 DRAWINGS ...
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......