C-6
1.5
CATASTROPHIC ERRORS
A catastrophic failure is generated each time the AC Power Supply experiences a hardware failure.
Errors are cleared whenever the AC Power Supply transmits a response, except in the case of a
short circuit fault which may only be cleared by cycling power to the AC Supply.
Catastrophic Error Messages
All begin with:
F00ACS0(DEV):
This message is followed by one explanatory message from the
following text:
OVERTEMP FAULT <cr><lf><eos>
The heatsink temperature has exceeded its upper limit. The
OVERTEMP LED on the front panel will light.
CURRENT LIMIT FAULT <cr><lf><eos>
SHORT CIRCUIT FAULT: AC SUPPLY<cr><lf><eos>
An output loading fault has occured causing the supply to exceed 500%
rated current output. The supply automatically shuts down and opens its
output relay. The OVERLOAD LATCH LED on the front panel will light.
Summary of Contents for BL10000 Series
Page 9: ...3 THIS PAGE BLANK FOR ADDENDUMS ALL MANUAL ADDENDUMS WILL FOLLOW THIS PAGE ...
Page 17: ...11 Figure 3 1 BL10000 AC Source Control Chassis Front and Rear Panel Views ...
Page 49: ...6 1 SECTION 6 DRAWINGS ...
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......