C-8
EIA-232 SERIAL PROGRAMMING EXAMPLES
3. EXAMPLE: Setup a dual range AC Source to output 115 V on high range @50 Hz, and read back what
the actual voltage, current, and frequency being output is set at.
Transmit setup command:
FNC ACS :CHO SET VOLT 115 SET FREQ 50 SET VLT1 <cr><lf><eos>
Transmit status command to request status response:
STA <cr><lf><eos>
Talk address the AC Source to enable response:
<space><cr><lf><eos>
: Positive response indicating status is OK.
Transmit output relay close command:
CLS :CHO <cr><lf><eos>
Transmit status command to request status response:
STA <cr><lf><eos>
Talk address the AC Source to enable response:
<space><cr><lf><eos>
: Positive response indicating status is OK.
Transmit fetch volt command:
FTH VOLT <cr><lf><eos>
Talk address the AC Source to enable response:
115.0 <cr><lf><eos>
Transmit fetch current command:
FTH CURR <cr><lf><eos>
Talk address the AC Source to enable response:
5.2 <cr><lf><eos>
Transmit fetch frequency command:
FTH FREQ <cr><lf><eos>
Talk address the AC Source to enable response:
50 <cr><lf><eos>