Configuration
TF6120
46
Version: 1.1
Signal Type
Beschreibung
0 : ReadCount
1 : WriteCount
2 : Random
Random-Function
3 : Ramp
Ramp-Function
4 : Sine
Sinus-Function
5 : Square
Square-Function
6 : Triangle
Triangle-Function
7 : Stepp
Step-Function
Disable
Deactivates the simulation
Save the configuration via "File" --> "Save As". After the configuration has been saved, you will be asked if
this configuration should be set as the startup-configuration.
The configuration will be automatically activated on next restart of the OPC-Server.
Step 2: Configuration of PLC-Variables for OPC-Simulation
With previous steps we defined a "simulation-template" with detailed information about simulation handling.
Now we define, which PLC variable should be handled with simulation. Similar to the Data Access feature,
this configuration also occurs by adding comments to the PLC-project.
Beispiel:
Please note:
Today just global PLC-variables can be linked to simulation-templates. Elements of structures or arrays can
not be configured as an OPC-Simulation.