Signal-Parameters
Type
Req./Opt.
Description
SignalID
Req
unique ID-number which identifies
this simulation-signal
SignalDesc
Optional
SignalType
Req
0 : Read Count
1 : Write Count
2 : Random
3 : Ramp
4 : Sine
5 : Square
6 : Triangle
7 : Step
8 : Reserver
9 : Step
Read Count
:
incremented by one every time
when the item is read
Write Count
:
incremented by one every time
when the item is written
Random:
generates random value within the
Amplitude range starting with
Position
Ramp
,
Sine
,
Square
,
Triangle
,
Step: (
periodical signals)
Their time behavior is influenced by
Period and Phase parameters.
Period specifies the signal
frequency, while Phase moves the
signal origin on the time
axisSquare and Triangle signal
types have one more parameter:
Ratio. Ratio defines Triangle signal
steepness, or Square signal H/L
proportions. NumSteps parameter
of the Step signal defines a number
of steps signal amplitude will be
divided into.
NumSteps
Optional, depends on
<SignalType>
Amplitude
Optional, depends on
<SignalType>
Period
Optional, depends on
<SignalType>
Phase
Optional, depends on
<SignalType>
Position
Optional, depends on
<SignalType>
Ratio
Optional, depends on
<SignalType>