Operation
EK1960
83
Version: 1.3.1
Fig. 94: Info data in the EK1960 tree structure
Info data of the internal EK1960 inputs and outputs
In addition to the project CRC and the serial number, the local inputs and outputs of the EK1960 connection
are shown under
Device Info Data
. The inputs, outputs, module errors and module ErrAck signals are shown
below the entry
Internal I/O
.
Fig. 95: Activating the info data for the local EK1960 connection
4.5
Version history
The
version history
button
under
Target System
can be used to read the version history of the EL6910,
EJ6910 or EK1960. It includes the user, the date, the version and the CRC of the safety projects loaded on
the EL6910, EJ6910 or EK1960.
Fig. 96: Version History