![Becker CentronicPLUS VC520 PLUS Assembly And Operating Instructions Manual Download Page 46](http://html1.mh-extra.com/html/becker/centronicplus-vc520-plus/centronicplus-vc520-plus_assembly-and-operating-instructions-manual_2718625046.webp)
Technical data
Rated voltage
110-240 V AC/50-60 Hz
Switching current AC
µ 3A/110-240 V AC
Switching current DC
µ 3A/30 V DC
Degree of protection
IP 20
Class of protection
(dependent on correct assembly)
II
Permissible ambient temperature
-25 to +50°C
Roller shutter/awning running time
1 s to 10 min. (default: 2 min.)
Venetian blind running time
1 s to 10 min. (default: 3 min.)
Switching actuator running time
1 s to 10 min. (default: no running
time)
Type of mounting
Device socket as per DIN EN 49073 /
DIN EN 60670
Surface mounted in appropriate sur-
face mounted housing
Max. cable cross-section
1.5 mm²
Radio frequency
868.3 MHz
Factory setting
Roller shutter
Dimensions (W x H x D)
45 x 42 x 22 mm