43
Tip:
Position newspaper or the like to protect the floor against fly ash before opening the combustion chamber
door.
–
Open the cladding door and ash door, empty the ash pan under the combustion chamber and the ash pan
for the heating surfaces (accessory) or remove the ash from the duct – Fig 126.
Assembly:
–
Push in the ash pan(s), close the doors.
–
Switch the FireWIN back on with the ON/OFF button.
Fig. 124
Connect the lever and operate it
Fig. 125
Switching off FireWIN
Fig. 126
Empty the ash pan(s) or remove the
ash from the heating surface duct
Always switch the boiler off first with the ON/OFF button (Fig. 125) and wait until burnout mode has
finished. Do not open the combustion chamber and ash door during operation.
3.5
Ash pan, ash on heating surface
Care, cleaning and maintenance
3.4
Heating surfaces
FireWIN Klassik and Premium
Optimum efficiency is achieved when the heating surfaces are cleaned as often as possible using the cleaning
lever. However, the cleaning lever should be connected on the right side and moved backwards and forwards
several time at the latest
before
the ash pan is removed or the ash removed from the heating surfaces –– Fig. 124.
Ash pan for
heating surfaces
(accessories)
When emptying the ash pan(s), remember that there could still be embers in the ash!
FireWIN Exklusiv
The heating surfaces are cleaned fully automatically after the set start times (see section 2.8.1.5) and when
approx. 15 kg of fuel has been consumed
⇒
on average 1x a day.