Operation
2.8.1.5
Probe switching
1)
If FireWIN is equipped with a fully automated pellet feed, it is pos-
sible to set here which probe is used for sucking pellets from the
pellet storage room. There are four different setting options:
–
Automatic:
Removal from all 3 probes, automatic switching.
–
Only probe 1: Removal from probe 1 only, no switching
–
Only probe 2: Removal from probe 2 only, no switching
–
Only probe 3: Removal from probe 3 only, no switching
Note: If „Pellet feed system, operation with 2 probes“ is set in the
„Service level“, the option of „Only probe 3“ is not displayed here.
Fig. 98
Fig. 99
Fig. 100
Fig. 101
Pressing one of the six buttons switches the lighting and display
on – Fig. 98.
Press the
Menu button – Fig. 99.
Confirm the selected menu item „Operator level“ by pressing the
Choose button – Fig. 100.
Use the
arrow buttons to select the „Probe switching“ sub-menu
item – Fig. 101.
Confirm the selected sub-menu item „Probe switching“ by pressing
the
Choose button – Fig. 102.
Fig. 102
Boiler temperature
(Operating phases)
Lighting ON
42
°C
Boiler temperature
(Operating phases)
Info
Menu
42
°C
Operator level
Service level
Choose
Back
Boiler cleaning
Time
Feed operating mode
Time profile feed
Probe switching
Time profile ash comp.
Choose
Back
Boiler cleaning
Time
Feed operating mode
Time profile feed
Probe switching
Time profile ash comp.
Choose
Back
1)
Only displayed if a feed system is present and if this has been adjusted by a
trained service technician in the service level.