12
2.4
InfoWIN
The InfoWIN is located at the top under the glass cover. Press the locking button at the front and fold the glass
cover open, the InfoWIN pops up automatically – Figs. 10, 11. It consists of a large full text display, an ON/OFF
button with an LED signal lamp indicating Operation (green) or Malfunction (red), a button for manual opera-
tion / flue cleaning function as well as four individual menu buttons. The function of each menu button is display-
ed on the Menu line.
5s
RESET
Full-text display
(illuminated display)
Manual operation / flue cleaning
function
Signal lamp (LED)
„Operation“ – green;
„Malfunction“ – red
Menu buttons
ON/OFF button
Menu line
Operating phases are
displayed here, including
Standby, Burner OFF, etc.
Assignment of buttons to
their specific function
Operation
The various operating modes are displayed on InfoWIN together with the corresponding operating phases.
The following
operating modes
exist:
–
OFF
–
ON (with self-test, lighting ON, lighting OFF)
–
Pellet feed
–
Solid fuel / buffer mode
–
Manual operation
–
Flue cleaning function
–
Shutdown procedure
Corresponding
operating phases:
–
Standby
–
Purging
–
Ignition phase
–
Flame stabilisation
–
Modulation mode
–
Burnout
–
Burner OFF
–
Switch off heat generator
è
Boiler temperature
Standby
Info
Menu
38
°C
Fig. 12
InfoWIN
Fig. 10
Press the locking button
Fig. 11
InfoWIN pops up