47
Care, cleaning and maintenance
–
Remove both knurled screws (Fig. 138) and fold open the inspection cover (Fig. 139).
– Remove dust (bridge formation) from the container and from both Fill level switch (proximity switch) using
a vacuum cleaner.
–
Close the inspection cover again and screw it on with knurled screws.
Fig. 138
Removing the knurled screws
Fig. 139
Folding open the inspection
cover, removing dust
Fig. 140
Removing the knurled screws
Fig. 141
Removing the coarse filter,
removing pellets and dust
–
Remove both knurled screws at the back from the coarse filter (Fig. 140) and remove the coarse filter (Fig.
141).
– Remove pellets and dust using a vacuum cleaner.
–
Put the coarse filter back on and screw it on with knurled screws.
Assembly:
By working through these steps in reverse order.
Fill level switch (proximity switch)