6. Remove the flue elbow from the adaptor.
7. Insert the flue duct into the air duct and pass them through the hole in the wall.
Page 19
IMPORTANT:
If the equivalent flue length is greater than 1.5m the restrictor
MUST
be removed from the adaptor (
Fig. 20
).
Fig. 20
8. Take one of the rubber seals and position it on the boiler flue adaptor. Engage the flue
elbow on the adaptor and pull the sleeve up so that it equally covers the joint (
Fig. 20
).
9. Remove the screws from one of the clips provided. Prise the clip apart and fit it over the
seal (
Fig. 21
). Set the elbow to the required angle.
Fig. 21