![Baxi 35/80 IE Installation & Servicing Instructions Manual Download Page 14](http://html.mh-extra.com/html/baxi/35-80-ie/35-80-ie_installation-and-servicing-instructions-manual_2711660014.webp)
Temperatures
C.H. Flow Temp (
adjustable
)
35°C to 85°C
max
(±5°C)
LPG Gases Propane - G31
Burner Injector
15 x 0.77mm diameter
Burner Pressure
Max Rate
Min Rate
Propane
mbar
34.4 ±0.5
5.1 ±0.5
in wg
13.8 ±0.2
2.0 ±0.2
Inlet Pressures
mbar
37
in wg
14.8
SEDBUK Declaration For System Boiler 60/100 IE
The seasonal efficiency (SEDBUK) is 78.2 %
This value is used in the UK Government's Standard Assessment Procedure (SAP) for
energy rating of dwellings. The test data from which it has been calculated have been certified
by 0051.
Page 8
5.0 Dimensions and Fixings
Dimensions
A
780mm
B
345mm
C
450mm
D
107mm Ø Min.
E
200mm
Summary of Contents for 35/80 IE
Page 15: ...F 190mm G 143mm ...
Page 20: ...Fig 5 ...
Page 51: ......
Page 55: ......
Page 57: ......
Page 59: ......
Page 67: ...br brown bk black b blue r red g green g y green yellow w white Page 39 14 0 Fault Finding ...
Page 69: ...Page 40 Fault Finding Solutions Sections A to E ...
Page 70: ...Page 41 ...
Page 71: ......
Page 73: ......
Page 74: ......