7 Sensor data sheet
General data
PosCon OXH7
11185166
OXH7-11185166
Function
Height
Function: Flex Mount
Yes
Function: FIELD OF VIEW
Yes
Measuring range (distance)
100…150 mm
Start of measuring range Sdc
100
End of measuring range Sde
150
Measuring range (width)
48…72 mm
Field of view width right @ Sde
+36 mm
Field of view width left @ Sde
-36 mm
Blind region
0…100 mm
Measuring frequency
- OBJECT light (approx. 90% refl.)
- OBJECT dark (approx. 6% refl.)
244…570 Hz
13
192…342 Hz
13
Response time
- OBJECT light (approx. 90% refl.)
- OBJECT dark (approx. 6% refl.)
3.5…8.2 ms
13
5.8…10.4 ms
13
AVG HEIGHT resolution
(max. field of view width)
8…16
µ
m
234
(without filter)
4…8
µ
m
2345
(with precision = high filter)
2…4
µ
m
2345
(with precision = very high filter)
MIN / MAX HEIGHT resolution
23…48
µ
m
23
(without filter)
12…24
µ
m
235
(with precision = high filter)
6…12
µ
m
235
(with precision = very high filter)
AVG HEIGHT repeat accuracy
(max. field of view width)
8
µ
m
234
(without filter)
4
µ
m
2345
(with precision = high filter)
2
µ
m
2345
(with precision = very high filter)
MIN / MAX HEIGHT repeat accuracy
16
µ
m
23
(without filter)
8
µ
m
235
(with precision = high filter)
4
µ
m
235
(with precision = very high filter)
Linearity error
±20
µ
m
2346
Temperature drift
±0.04% Sde/K
234
PRECISION filter values:
Standard
High
Very High
Median Average
Off Off
3 Off
3 16
Smallest detectable object
0.7…1.1 mm
Laser class
1
Max. reference surface unevenness (rms)
±0.04 mm
Min. reference surface length
24 mm
Digital output hysteresis
Adjustable in mm
Minimum switching window
2 mm
Power on indication/data transmission
LED green/LED blue
Output indicator
Yellow LED / red LED
Light source
Red laser diode, pulsed
Setting
Web interface, Modbus TCP, OPC UA
1
Measurement rate subject to measuring range (distance). Min. value: maximum field of view; max. value: 20% of field of view
2
Measurements with standard Baumer measuring equipment and objects dependent on measuring range Sd
3
Measurement on 90% reflectivity (white)
4
Measurement with Average measurement mode
5
Measurement with filtering
6
Measuring range (distance) 100…112.5 mm