4 Communication via the process interfaces
4.1 Introduction
In addition to the configuration option via the integrated web server, the sensor supports Modbus TCP and
OPC UA – two standardized automation technology protocols for configuring and retrieving measurement
values.
4.1.1
Dependencies
The sensor supports one client connection for each protocol. Read access via the protocols is possible at any
time. Write access is only permitted once the sensor has been moved to Configuration mode via the
respective interface. Only one interface can be in Configuration mode at one time. The measuring frequency
that can be achieved may be reduced in such cases.
4.1.2
Description of the commands
See chapter "Configuration via the web interface".