Network
Choice between static and dynamic address configuration using DHCP. If DHCP fails, the static address is
used.
Static IP address
The device uses a set IP address. This requires the IP address, subnet mask, and the standard gateway to be
specified.
DHCP (Dynamic Host Configuration Protocol)
If a DHCP server is integrated in the same network, the IP address is determined from there. If this does not
happen within a specific time and a timeout occurs, the set IP address specified below is used.
3.4.3
Time Synchronization
Activation/deactivation of the NTP synchronization. If activated, the sensor synchronizes its internal clock with
the defined network time server.
The time stamps for the measurement values are set based on the synchronization. The time basis is UTC.
Note: The daylight saving time functionality is not supported.
3.4.4
Process Interface
Activate or deactivate the Modbus TCP and OPC UA functionality by toggling the "on / off" button. When set to
"off", the sensor no longer responds to requests via this protocol.
3.4.5
Parameter Setup Overview
Displays the stored values for the parameter setups. The parameter setups are presented in a general
overview here.
3.4.6
Update Web Interface & Factory Reset
A new web interface can be uploaded and the factory settings reset here.
Displays the web interface version and date. "Update Web Interface" updates the web interface if a new
version has been released.
Activating "Factory Reset" resets the device to the factory settings.