Address 300 – Switching Output Configuration
Function
Holding register (FUNCTION 03/06/16)
Address
300
Length
11
Address
Parameter description
Data type
300-301
Switch Point 1
float32_t
302-303
Switch Point 2
float32_t
304-305
Switch Mode
int32_t
306-307
Hysteresis
float32_t
308-309
Measurement Value
0 = Average
1 = Max
2 = Min
3 = Delta
4 = Standard Deviation
int32_t
310
Polarity
0 = Active Low
1 = Active High
uint16_t
Address 400 – Get Trigger Mode Settings
Function
Holding register (FUNCTION 03/06/16)
Address
400
Length
8
Address
Parameter description
Data type
400-401
Trigger Mode
0 = FreeRunning
1 = SingleShot
2 = Interval
3 = Internal (not settable)
int32_t
402-403
Fixed Trigger Time [us]
uint32_t
404-405
Minimal Fixed Trigger Time [us] (command does not care
which number is written)
uint32_t